图片名称

What is the skill of using the reducer?

2018-08-21 20:08

1. After 200~300 hours of operation, the oil should be changed for the first time. In the future use, the quality of the oil should be checked regularly. For the mixed impurities or deteriorated oil, it must be replaced in time. Under normal circumstances, for gearboxes that work continuously for a long time, replace the new oil with 5000 hours of operation or once a year. The gearbox that has been deactivated for a long time should be replaced with a new oil reducer before re-running. It should be added with the same oil as the original grade. It must not be mixed with different grades of oil. Oils with the same grade and different viscosity are allowed to be mixed.

2. During work, when the oil temperature rise exceeds 80 °C or the oil pool temperature exceeds 100 °C and abnormal noise is generated, stop using it. Check the cause, remove the fault, and replace the lubricating oil before continuing operation. .

3. The user should have reasonable rules for the use and maintenance. The operation of the reducer and the problems found in the inspection should be carefully recorded. The above provisions should be strictly implemented.

4. When changing oil, wait for the reducer to cool down without burning danger, but still keep warm, because after the complete cooling, the viscosity of the oil increases, and it is difficult to drain the oil. Note: Turn off the power supply of the transmission to prevent unintentional power-on!

Related News

Shanghai Branch held the opening ceremony

OnMarch2nd,theopeningceremonyofShanghaiBranchandZhongtianFuchuan(Shanghai)EngineeringTechnologyDevelopmentCo.,Ltd.washeldinQiluNo.1Hotel,YangpuDistrict,Shanghai.YangDecheng,ChairmanoftheGroup,LiuYanqi

2019-03-11


Zhongtian Technology Holdings Group leaders celebrate the New Year and hold the "first meeting" of the New Year

OnFebruary11,thefirstdayoftheseventhdayofthelunarcalendar,at8:30,thechairmanofShandongZhongtianTechnologyHoldingsGroup,YangDecheng,generalmanagerLiuYanqiu,deputygeneralmanagerWeiRuizhu,SunAilingledthe

2019-02-13


What is the difference between a shielded pump and a magnetic pump and a centrifugal pump?

The fully sealed, or leak-free, construction of the shielded pump makes it ideal for pumping flammable, expensive, corrosive and toxic liquids. Because the shield pump does not leak, it contributes

2018-11-09


North American polyolefin industry production prospects are promising

At a recent global plastics conference in Chicago, USA, analysts said that prospects for polyolefin producers in North America are promising.

2018-11-09